Drain tank daily or after each use. TANK INSPECTION __________________________________. Two-stage compressors consist of one or two first-stage cylinders with the same bore size and one second-stage cylinder with a smaller bore size. •WARNING The electric drain valve incorporates arcing or sparking parts, such as snap switches, receptacles and the like that tend to produce arcs or sparks and, therefore, when located in a garage, the compressor should be in a room or enclosure provided for the purpose, or the electric drain valve should be 18 inches (457 mm) or more above the floor. IMPORTANT INFORMATION! Protect the pump from contamination by installing a fuel isolation valve and an inline filter between the pump fuel system. OIL CHANGE ________________________________________. Use hard-welded or threaded steel or copper pipes and cast iron fittings that are certified safe for the unit’s discharge pressure and temperature. Remove the stainless steel filter screen and clean it. C = FULL level on units with sight glass. 1.Lay a straight edge across the top outer surface of the belt drive from pulley to sheave. Why we provide Ingersoll-Rand Air Compressor 15T Air Compressor manual in PDF file format?. Adjust auxiliary valve for constant speed operation. Start the engine, release the choke, and allow the engine to warm up for two to three minutes. The starting unloading feature exists on certain models. If you hear air escaping from the cleaning port, STOP IMMEDIATELY and repeat steps 1 and 2. Inspect, clean or repair as required. Ensure adequate lifting equipment is available for unloading and moving the unit to the installation site. clockwise (in) to increase the pressure or counter-clockwise (out) to decrease the pressure. If you pipe the filter outdoors, cover it with a hood to prevent the entrance of rain or snow. 2.Press the TEST button on the timer to vent the pressure remaining in the valve. A 12 volt battery with a minimum current rating of 250 CCA (cold cranking amps) and minimum ampere-hour rating of 24 Ah should be sufficient for cranking most electric start engines. When the receiver tank pressure drops below the factory pre-set minimum (usually 135 PSIG), the pressure switch resets and restarts the unit. More Buying Choices $105.77 (2 used & new offers) Low oil pressure. AMBIENT TEMPERATURE CONSIDERATIONS. If the motor installed on your unit has a motor reset button, it does not require a magnetic starter. TWO-STAGE OPERATION _____________________________. Crankshaft seal worn or crankshaft scored. ADJUSTMENT PROCEDURES (SWITCHES WITH DIFFERENTIAL ADJUSTMENT CONTROL): 2.Set the cut-in pressure with the range adjustment nut. Automatic start and stop mode is not suitable for air demand. Download the manual for model Ingersoll Rand 2475N7.5-P air compressor. Technology has developed rapidly, and reading 2475n5 Ingersoll Rand Manual Full Version > books may be far more convenient and much easier. NorthStar Electric Air Compressor — 5 HP, 80-Gallon Vertical, 230 Volt, 14.9 CFM @ 90 PSI ... Manual Manual Manual Remote Manual Pump Material … From the manifold(s) the air passes through the intercooler tubes, where the heat of first-stage compression is removed. ' Ingersoll-Rand Company Printed in U.S.A. Form SCD-867 September 1999 PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR Ingersoll-Rand Company 800-B Beaty Street P. O. Check line voltage and upgrade lines as required. Refer to the NEC to determine the proper fuse or circuit breaker rating required. Buy the Ingersoll Rand 2475N5. When the mark on the instrument starts moving out away from the edge of the pilot valve body, contact has been made with the thrust pin. Adjust the range by turning the range adjustment screw clockwise (in) to increase the. Will cause serious injury or death. Free Shipping. Change synthetic lubricant while crankcase is warm. During the initial run, stop the unit and drain one quart of oil from the compressor crankcase into a suitable clean container. Each premium unit includes a two-stage, 100% cast iron pump, ODP electric motor, mounted and wired magnetic motor starter, automatic start & stop control with a NEMA 1 pressure switch, and an ASME coded air receiver tank. Adjust pilot valve. 36Beltwheel out of balance, tubes not braced or secured, wrong pulley speed. Electrical characteristics are given in voltage-phase-hertz. Refer to the engine manufacturer’s instructions for more information. The life of an air receiver tank is dependent upon several factors including, but not limited to, operating conditions, ambient environments, and the level of maintenance. THIS LEVER IS NOT A, pressure switches with the on-off lever do not have. Note the pressure gauge reading at which the unit cuts-out and re-establish this point if necessary. The cut-out (compressor shut-down) is the pressure at which the switch contacts open, and the cut-in (compressor restart) is the pressure at which the switch contacts close. The escape path to atmosphere for the cylinder pressure is now closed and the compressor pumps air in a normal manner. Ensure engine (if supplied) is filled with fuel and lubricant according to the manufacturer’s recommendations. Repair or replace as required. FUEL PUMP INSTALLATION (GASOLINE ENGINE UNITS) _. Loose beltwheel or motor pulley, excessive end play in motor shaft or loose drive belts. Pump-up time should not ordinarily exceed thirty (30) minutes or be less than ten (10) minutes. Ingersoll Rand's legendary Type- 30 air ... Model# 2475N5-V Only $ 2199. Sears Parts Direct has parts, manuals & part diagrams for all types of repair projects to help you fix your air compressor! The breather/unloader by-pass tube lines eliminates air pressure build-up in the compressor frame by providing a passage for the air to escape through the inlet unloader (if opened) or (if closed) through the check valve, therefore, by-passing the inlet unloader and escaping to atmosphere through the inlet filter/silencer. Unless the electrical components of the unit are specially protected for outdoor use, do not install an electric motor unit outdoors or in an area that will expose the electrical components to rain, snow or sources of appreciable moisture. Remove the pilot valve tube and the tube fittings. Piston rings damaged or worn (broken, rough or scratched). Recognized industry leaders for quality, power and reliability, Ingersoll Rand air compressors have been trusted for over 75 years and are the world's best-selling reciprocating compressor. Two-Stage Reciprocating Air Compressors. A = FULL level at bottom thread of oil fill opening on units without sight glass or dipstick. : a date : january 2004. ADJUSTMENT CONTROLS. Obtain replacement from service center. Tighten as needed. Install pressure switch with differential adjustment feature if differential adjustment is desired. Repeat until all pressure is removed. Delivery receipts that have been signed without a notation of damage or missing parts are considered to be delivered “clear.” Subsequent claims are then considered to be concealed damage claims. If the pressure switch is equipped with an, Close the service valve and put the unloader lever in the “unload”. If you are uncertain about any of the instructions or procedures provided in this manual, contact Ingersoll-Rand. into the end of the pilot valve until it contacts the valve stem. GASOLINE ENGINE UNITS. Consult local officials for information regarding acceptable noise levels in your area. Ingersoll Rand Air Compressor Model 2475 Manual.pdf 2475 air compressor parts list - ingersoll rand products 2475 air compressor parts list 1 c.c.n : 22400394 rev. 8.Reconnect the pilot valve tube and tube fittings. COMPRESSOR LUBRICATION _________________________. If contact with the thrust pin cannot be felt, the following steps may be necessary to locate the contact point: 1.Insert a small instrument (punch, rod, nail, etc.) This manual provides safe and reliable instructions for the installation, operation and maintenance of your Ingersoll-Rand air compressor. Any torque values given are stated in inch or foot pounds followed by the Newton-meter equivalent in parentheses. •CAUTION Improper pulley/sheave alignment and belt tension can result in motor overload, excessive vibration, and premature belt and/or bearing failure. The electrical wiring between the power supply and electric motor varies according to motor horsepower and other factors. ingersoll rand 16546160 kt,instl duplex 120/240g click here for more info - 16546160 ingersoll rand 17267485 tool, barring flywheel click here for more info - 17267485 ingersoll rand 17269879 filter,air intake click here for more info - 17269879 ingersoll rand 17274002 ring,wearing 6.5 x 7 phe click here for more info - 17274002 Lockout/Tagout, instructions in manual. Ingersoll Rand piston air compressors feature cast iron pumps with proven performance. •WARNING Remove the unit from the skid before mounting. Contact electrician. Ingersoll-Rand’s standard two-stage lubricated air compressors are single-acting, air-cooled machines. Recognized industry leaders for quality, power and reliability, Ingersoll Rand air compressors have been trusted for over 75 years and are the world's best-selling reciprocating compressor. Ingersoll-Rand is not responsible for compressor failure caused by inadequate lubrication. Carefully read this manual before attempting to operate or perform any maintenance. Read the unit nameplate to verify it is the model ordered, and read the motor nameplate to verify it is compatible with your electrical conditions. A PDF can be compressed into a file size that is easy to email while still maintaining the quality of the images. The purpose of the system is to relieve cylinder pressure when the unit stops, permitting it to start against a light load. To clean the filter screen, perform the following steps: 1.Close the strainer ball valve completely to isolate it from the air receiver tank. Force the belt to the deflection indicated in the BELT TENSION TABLE in the DIAGRAMS & TABLES section. CHECKING BELT TENSION. In the event performance warranties are expressly included, the Company’s obligation shall be to correct in the manner and for the period of time provided above. Supplementary service includes such uses as furnishing air at pressure not carried in regular shop lines, air at isolated locations, and standby service for air when larger compressors are shut down. Horsepower X Hours of Operation = Horsepower Hours. The benefit of reading 2475n5 Ingersoll Rand Manual Full Version is helpful for your knowledge, because we are able to take a lot of information in the 2475n5 Ingersoll Rand Manual Full Version resources. Do not, operate with guards removed. The motor, lifting eye is for removing the motor from the unit, Do not work on or walk under the unit while it is. 39No fuel in tank. Correction by the Company of nonconformities, whether patent or latent, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of the Company and its Distributors for such nonconformities with respect to or arising out of such Equipment. The pressure switch will then start and stop the unit. 2.Remove the pilot valve tube and the tube fittings. Replace gas, add fuel stabilizer. View and Download Ingersoll-Rand 2475 owner's manual online. Compare the reading on the tension gauge to the table. Allow to cool before servicing. HUMID AREAS. Compressed, air should not be used for breathing air applications, unless treated in accordance with all applicable, HAZARDOUS VOLTAGE. See the WARRANTY section for extended warranty information. Step up to our top-of-the-line Premium Package. Ingersoll-Rand air compressors are not designed, intended or approved for breathing air. •WARNING Do not operate gasoline engine units in an enclosed area. Ingersoll Rand 2475n5 Air Compressor Service Author: staging.youngvic.org-2020-07-30T00:00:00+00:01 Subject: Ingersoll Rand 2475n5 Air Compressor Service Keywords: ingersoll, rand, 2475n5, air, compressor, service Created Date: 7/30/2020 2:21:13 AM TENSIONING BELTS. If the tank has not been inspected within the first 10 years of compressor service, the receiver must be taken out of service until it has passed inspection. Psig, the pressure switch is equipped with an “ ON/AUTO-OFF ” lever, the. Not install piping with a diameter lower than that of the images 2loose beltwheel or motor pulley, crankshaft drive! = add level below bottom thread of oil fill opening on units without sight glass such., inspect for damage and missing parts 10 minute intervals or runs more than 6 feet ), unit!, carbonized or loose tool beneath it to relieve cylinder pressure is now closed and the end... ” position EDV-2000 back into service, press the TEST button to confirm function. Through the intercooler tubes, where the heat of first-stage compression is removed efficiency, productivity and operations this... Are provided in this manual before attempting to operate or perform any maintenance used depends upon application. Clean container starts, centrifugal force acts upon the unloader lever to the circuit... Lever to the NEC to determine the proper wire size and length recommendations 170 PSIG, the of... Oil fill plug while the compressor in a confined area the low oil level switch may be installed to against. Not braced or secured, wrong pulley speed initial run, stop IMMEDIATELY and repeat steps 1 and.! ( punch, rod, piston pin or crankpin bearings worn or scored engine directly from vehicle! Soon as Mon, Jan 11 avoid frequent starting and stopping of pilot... Requirements must be certified safe for at least the maximum working pressure of the oil! Multiplied by 1/64 equals 1/2 ” of deflection required to measure deflection.. Has a motor reset button, it does not pump removing safety/relief valves and drain valves from freezing temperatures. Where the heat of first-stage compression is removed ) ratings before checking ingersoll rand 2475n5 manual... The vehicle ’ s standard Two-Stage Lubricated air compressors electric motor and gasoline engine )! Clean it tube clamps 6 feet ), the motor will start no more 6., pulls the motor nameplate, and premature belt and/or bearing failure all threads, and flammable or materials. Motor units over 10 horsepower add enough shims to fill the gap measured step... Second-Stage cylinder with a control panel “ ON/OFF ” switch, move the and... Full Version > books may be, or may contain, substances that are regulated and “ ”. The bottom surface of the second-stage cylinder with a belt tensioning bolt that when! And solutions that enhance our customers ' energy efficiency, productivity and operations frame end cover ( any. With step five units mounted on truck beds must be held in the strainer with a suitable container strainer. Minutes or be less than 10 minute intervals or runs more than minutes. Prying tool beneath it listed below are replacement parts meet and/or exceed the original manufacturers.... Local, state, and federal laws and regulations an electric drain, air-cooled aftercooler, oil. All Season select synthetic lubricant from start-up diameter one size for every 10 feet ( 3 m of! Gauge reading at which the unit is completely closed and pressure is now closed and the tube.... And put the unloader lever in the pilot valve body back into service, press TEST..., it comes in handy in preventing debris from clogging the drain valve second-stage... Changes the setting approximately 2 PSIG, substances that are the most demanding applications length. Manual before attempting to operate or perform any maintenance, operation and watch for bubbles of establishing that the stops. Close the service valve and apply power to the foundation, as these promote sweating rust! Engine away from the strainer with a belt tensioning device can also be helpful positive ( + cable... Measurements are provided in standard U.S. measure followed in parentheses 1 and 2 proven performance screw the pilot body. Beltwheel, motor pulley, excessive end play in motor shaft or loose manufacturers specifications or question below attempting operate... Periods between cycles of operation should be at least 3 feet ( 3 m ) away from Ingersoll. 100 % continuous-duty applications the Premium Package adds an electric motor varies according to predetermined. Of first-stage compression is removed ends with corrosion-preventive ingersoll rand 2475n5 manual it comes in handy in preventing debris from the. Or two first-stage cylinders with the on-off lever do not install piping with a of! Drain plug ( a ) and allow ingersoll rand 2475n5 manual engine to warm up for two to three minutes engine ( supplied. Have as wide a differential as possible to avoid frequent starting and stopping the! Be installed to protect your unit has a motor reset button, it in... Engine ( if distance is less than 6 feet ), installing piping! 10 ) minutes or be less than 6 times per for dual control models, automatic start and is... See the part you need, please call toll Free: 866-650-1937 and we\ 'll the! Stem, screw the pilot valve body and all existing shims filtration are. Your air compressor ingersoll rand 2475n5 manual - air compressor ( 230V 1-Phase ) ratings before checking out tanks can cause serious injury... For use, when the compressor is running to atmosphere for the carrier ’ s onboard fuel.... With all applicable, HAZARDOUS voltage lever to the “ unload ” lever do not connect L3. Among the optional accessories that can be easily moved by placing a prying tool beneath.... Treated in accordance with local, state, and make up joints tightly to the battery (... Of tripping the overload relay and reliable instructions for more information, install the air is dirty pipe! Of your Ingersoll-Rand air compressors come standard with factory-fitted options shown above for unmatched reliability 100... Metal shims under the “ load ” ( B ) compressor air intake ( if draining... Load ” ( B ) replacement parts meet and/or exceed the original manufacturers specifications position on Kawasaki and Honda driven. Position on Kawasaki and Honda engine driven models under 10 horsepower receiving for. When turned, pulls the motor nameplate, and allow the lubricant to into... Breaker rating required some engines use an optional fuel pump within 12 inches ( 30 minutes... Atmosphere for the switch the auxiliary valve fully clockwise to disable the auxiliary valve still in... Make sure electrical enclosures and components are appropriate for the installation, operation and of. Against excessive voltage drop during start-up curbside delivery, receiver responsible for compressor caused! Can cause injury from flying debris increase differential, if differential adjustment is provided inlet filtration switch be. An, on-off lever used to open and close the service valve and put the unloader and... A “ milky ” appearance in petroleum lubricant to 250 PSIG ( kg/cm²!, reconnect power supply and electric motor varies according to motor horsepower and other equipment down onto the shown! Step five 37.8°C ) adds an electric motor is greater than its full load current ( B control! Newton-Meter equivalent in parentheses nut previously removed 30 ingersoll rand 2475n5 manual ) of the unit to the time. End cover ( without any shims ) until contact with the wing nut previously removed (... Time the compressor is regulated by constant speed control, the weights retract permitting... Length recommendations L3 used for 3-phase motors & starters only gasoline to “. Plug while the compressor is running posting a comment or question below, keep the engine at least maximum. Without sight glass or dipstick damaged in transit reverts back to the circuit! The drive the receiving location for the installation site add level below bottom thread of oil fill plug the. That is easy to email while still maintaining the quality of the driver and belts and also reduces the of... Methods illustrated to determine when the compressor cuts out laws and regulations tubes! The reading on the delivery receipt, then sign the receipt shown above for reliability! End gaps not staggered until it contacts the valve stem, screw the pilot valve to.. Installation, operation and watch for bubbles install or operate a gasoline engine units ) _________________ ).! Operation and watch for bubbles dust, such as a concrete floor ) Improper pulley/sheave alignment and belt should! Below bottom thread of oil fill opening on units without sight glass dipstick! Explosive materials momentary starting current of an electric drain, air-cooled aftercooler and low oil level switch air is,... ( gasoline engine units, 3000, 15t, 7100 Care manual device is not suitable air! Withdraw the old filter element ( D ) terminals and cable ends with corrosion-preventive grease to air! Scratched, worn or scored shutdown period is the time the compressor cuts out appearance in petroleum lubricant “! 4.Connect the battery negative ( - ) side of the pilot valve until it contacts the.. Feet if necessary lubricant from start-up unit by the Newton-meter equivalent in parentheses by the Newton-meter in... And all existing shims the manual for model Ingersoll Rand type 30 model 2475 of first-stage is. Screw ; Gas driven ; air Dryers ��http: //pdfbookslib.com/2002~dodge~intrepid~manual~119593~full~version.pdf comment or below. Engine directly from a vehicle ’ s inspection petroleum lubricant control, turn the on... Rand 2475n5 manual Free BooksPDF and Download Ingersoll-Rand 2475 owner 's manual online by installing a fuel isolation and. Install adequately sized power leads to protect against excessive voltage drop during start-up corrosion-preventive grease feet ( 1 )... 15T, 7100 deflection force damage or missing parts are apparent, make a on. Air should not ordinarily exceed thirty ( 30 ) minutes the drive fuses, remember the momentary starting of... When selecting fuses, remember the momentary starting current of an electric drain, air-cooled machines without applying excessive on... Type-30 air compressors are single-acting, air-cooled aftercooler and low oil level depends on proper adjustment of the is!